The
IR-M1000 Series is reflection system on-line moisture meters utilizing
the infrared absorption of moisture. Converting capabilities are built
into the compact designed detector unit for easy installation and operation.
Maximum 99 calibration curves can be stored into memory for many applications.
The unit can be used by itself or by combining with personal computers
as an analog output and a communication function are provided with. A setting
display unit connectable with maximum 9 detector units can set various
kinds of setting items of the detector unit and displays moisture value. |
 |
 |
Detector unit
|
Measuring system |
Infrared reflection type 3-wavelength
system (2-wavelength system for micro moisture
type) |
|
Measuring distance |
300 mm (Distance of 200 to 400mm is
possible.) |
|
Measuring area |
About 50 x 50mm (at measuring distance of
300mm) 30
x 30mm for small diameter type (30 x 30mm/measuring distance 200mm for
micro moisture type) |
|
Moisture output |
4 to 20mADC (Load resistance: less than
500 ) Correction input: 4 to 20mADC
(option) (For correction of sample temperature,
measuring distance, etc.) |
|
Communications output |
RS-485, RS-232C or RS-422A (to be
specified) RS-485 for connection with the
setting display unit |
|
Output renewal cycle |
28ms |
|
Display |
LED 5-digit Calibration curve number -
LED 2-digit |
|
Setting |
By keys or communications |
|
Calibration curve |
Linear to cubic expression or broken
line |
|
Numbers of calibration curve |
99 curves |
|
Calibration curve correction |
Zero and span correction |
|
Calibration curve creation |
Regression calculation |
|
Calibration |
By a checking plate |
|
Smoothing |
0 to 99 seconds |
|
Working temperature range |
0 to 50°C(Air is necessary for more than
45°C.) |
|
Rated supply voltage |
24VDC |
|
Power consumption |
Maximum 36VA |
|
Connection |
Terminals connection |
|
Casing |
Aluminum casing, drip-proof structure
(conforming to IEC529 IP65) |
|
Mounting |
Suspension system using four M8
bolts |
|
Weight |
About 4kg |
|
Accessory |
Power supply unit
IR-WEP |
|
* Models complying with explosion-proof
construction [ExdIIBT4] are available. |
|
Setting display
unit
|
Detector unit input |
RS-485, connectable with up to 9 detector
units |
|
Analog output |
4 to 20mADC (Load resistance: less than
500 ), 2
outputs |
|
Communication output |
RS-232C, RS-485 or RS-422A (to be
specified) |
|
Output renewal cycle |
28ms x (quantity of detector
unit) |
|
Display |
Data - LED 5-digit Calibration curve
number - LED 2-digit Detector unit number - LED
1-digit |
|
External setting |
Setting of detector unit number,
calibration curve number, calibration, preset
output and hold by external contact |
|
Alarm |
High/low alarms, Contact 2 outputs
(H-C-L) |
|
Working ambient temperatur |
0 to 50°C |
|
Rated supply voltage |
100 to 240VAC 50/60Hz |
|
Power consumption |
Maximum 15VA |
|
Casing |
ABS resin, Front panel - Drip-proof
structure (conforming to IP-65) |
|
Weight |
About 0.6kg |
|
Power supply
unit
|
Output voltage |
24VDC |
|
Output current |
2.1A |
|
Working ambient temperature |
0 to 50°C |
|
Supply voltage |
100 to 120VAC, 200 to 240VAC, switching
type, 47 to 450Hz |
|
Power consumption |
Maximum 160VA |
|
Weight |
About
380g |
|
CE conformance
|
Analog output
|
4 to 20mADC (Load resistance: less than
500 ),1
output (1) Output accuracy - ±0.5%of full
scale (2) Stability - ±3% of full scale under
EMC test environment |
|
Rated power supply |
24VDC, allowable voltage fluctuation - ±10%
of rated value |
|
Power consumption |
About 10VA <Standard> EN55011 group 1
class A, EN50082-2 (industrial
environment) <Directive> 89/336/EEC,
92/31/EEC (amendment), 93/68/EEC
(amendment) |
|
Package software
IR-WEF1(for IR-M1000, IR-M2000)
|
Contents |
Data logging, trend display,
data storage and calibration curve creation Up to 9 detector unit s are
connectable. An electronic balance is connectable
on the creation of calibration
curve. |
|
Environment |
DOS/V PC |
|
OS |
Windows 95, 98, 2000 Contact input board
(option): IBX-2131 (ISA bus)
|
|
|