The IR-M2700 Series is fiber
optic on-line thickness meters for the measurement of
thickness of polymer films and of coating volume of
papers and polymer films utilizing the infrared
absorption of moisture. The sensing part is a fiber
optics and can be installed at narrow space and high
temperature environment.
Converting capabilities are
built into the compact designed detector unit for easy
installation and operation. Maximum 99 calibration
curves can be stored into memory for many applications.
The unit can be used by itself or by combining with
personal computers as an analog output and a
communication function are provided with.
A setting display unit
connectable with maximum 9 detector units can set
various kinds of setting items of the detector unit and
displays moisture value. |
 |
 |
Detector unit
|
Measuring system |
Infrared reflection type 2-wavelength
system |
|
Thickness output |
4 to 20mADC (Load resistance: less than
500 ) |
|
Correction input |
4 to 20mADC
(option) (For correction of
sample temperature, measuring distance,
etc.) |
|
Communications output |
RS-485, RS-232C or RS-422A (to be
specified) RS-485 for connection with the
setting display unit |
|
Output renewal cycle |
28ms |
|
Display |
Data - LED 5-digit Calibration curve
number - LED 2-digit |
|
Setting |
By keys or communications |
|
Calibration curve |
Linear to cubic expression or broken
line |
|
Numbers of calibration curve |
99 curves |
|
Calibration curve correction |
Zero and span correction |
|
Calibration curve creation |
Regression calculation |
|
Calibration |
By a checking plate |
|
Smoothing |
0 to 99 seconds |
|
Working temperature range |
0 to 50 °C (Air is necessary for more than
45°C.) |
|
Rated supply voltage |
24VDC |
|
Power consumption |
Maximum 36VA |
|
Connection |
Fiber - Connector
connection Power supply/signal line - Terminal
connection |
|
Casing |
Aluminum casing, drip-proof structure
(conforming to IEC529 IP65) |
|
Weight |
About 4kg With a power supply unit
IR-WEP |
|
Fiber optics
|
Measuring distance and measuring
diamete |
Reflection type - 20mm at 15mm,
50mm at 50mm Reflection type with lens
-
25mm at 25mm,
40mm at 100mm |
|
Fiber length |
Reflection type, Reflection type with lens
-1.5m (up to 10m) Transparent type- 2m (up to
20m) |
|
Allowable bending radius |
Reflection type,
Reflection type with lens - R100mm Transparent
type - R250mm |
|
Working temperature range |
0 to 150°C |
|
Purge air flow |
Reflection type - 5 to
20Nl/min Reflection type with lens - Without
air purge function |
|
Setting display
unit
|
Detector unit input |
RS-485, connectable with up to 9 detector
units |
|
Analog output |
4 to 20mADC (Load resistance: less than
500 ), 2 outputs |
|
Output renewal cycle |
28ms x (quantity of detector
unit) |
|
Display |
Data - LED 5-digit Calibration curve
number - LED 2-digit Detector unit number - LED
1-digit |
|
External setting |
Setting of detector
unit number, calibration curve number,
calibration, preset output and hold by external
contactAlarm: High/low alarms, Contact 2 outputs
(H-C-L) |
|
Working ambient temperature |
0 to 50°C |
|
Rated supply voltage |
100 to 240VAC 50/60Hz |
|
Power consumption |
Maximum 15VA |
|
Casing |
ABS resin, Front panel - Drip-proof
structure (conforming to IP-65) |
|
Weight |
About
0.6kg |
|
Power supply unit
|
Output voltag |
24VDC |
|
Output current |
2.1A |
|
Working ambient temperature |
0 to 50°C |
|
Supply voltage |
100 to 120VAC, 200 to 240VAC, switching
type, 47 to 450Hz |
|
Power consumption |
Maximum 160VA |
|
Weight |
About 380g |
|
 |
|