LE5000 Series Intelligent Recorders Download PS Sheet

LE5000 series are 250mm hybrid recorders with multi-range input. Innovative design high performance recorder provides high accuracy, ±0.05%; high speed scanning, 0.1second for 36 points and high speed recording, 1 line in 3 seconds. Simple operational keys and PC setting functions drastically improved usability of recording system.   LE5000 Series
Features Models Specifications Accessories
Input Signals
Recording Specifications
Display Specifications
Alarm Specifications
General Specifications
Optional Specifications
Communication interface Specifications
 
Input Signals

Measuring points : 12, 24 and 36 points
Input : Multi-channel data range
DC voltage --- ±10mV, ±20mV, ±40mV, ±80mV, ±1.25V, ±2.5 V, ±5 V, ±10V DC current --- Shunt resistor (100Ω, 250Ω) needs to be mounted externally Thermocouple --- B, R, S, K, E, J, T, N, PtRh40-PtRh20, NiMo-Ni,WRe5 – WRe26, W-WRe26, Platinel II, U, L
Resistance thermometer --- Pt 100, JPt 100
Range setting: Input type and range are set with front keys
Scale setting: The minimum and maximum values and unit are set for each point with front keys Setting range -30000 to 30000
Decimal points Optional setting
Indication accuracy: Refer to items of measuring ranges, accuracy rating and display resolutions
Temperature drift: 0.1% FS/ 10°C
Measuring period: 0.1 sec/ channel
Reference junction compensation accuracy: K, E, J, T, N, Platinel II --- ±0.5°C or less (0℃°C or more when measuring) R, S, WRe5-WRe26, NiMo-Ni, U, L --- ±1.0°C or less (Only when the ambient temperature is 23°C±5°C)
Input resolution: Approx. 1/40000 (Standard range conversion)
Burnout: Select with/ without burnout for each input
Allowable signal source resistance: Thermocouple inputs, DC voltage input (10mV) --- 500Ω or less (without burnout) DC Voltage input (except 10mV) --- 100Ω or less Resistance thermometer inputs --- 10Ω or less/ line Three lines are common, Pt100, JPt100
Input resistance: Thermocouple input, DC voltage input --- approx.1MΩ
Maximum input applied voltage: ±20V DC
Input correction: Zero/span correction and shift correction for each channel
Maximum common mode voltage: 30V AC (support LVD) *250V AC at evaluation
Common mode rejection ratio: 130dB
Series mode rejection ratio: 50dB (Only when the peak value of noise is below standard range.)
Terminal board: Detachable type, removable for wire connection
Recording Specifications

Recording system : Raster scan system, 10-color wire dot printing
Recording and recording color : Analog recording --- color can be specified for each channel as required. 10 colors (red, purple-red, orange, brown, green, yellow-green, blue-green, purple, purple-blue, black) Digital recording and logging recording - Black Message printing --- Black List printing --- Black
Chart paper: Fan-fold type, Overall width 318 mm, total length 20m; Effective recording width 250mm (analog recording)
Chart speed: 1 to 1500mm/H (in 1mm/H steps)
Skip function: Analog recording, digital recording and digital display can be set independently from recording slip.
Recording compensation: Independent setting of zero spans are available.
Display Specifications

Digital display: Color LCD panel RGB (640 x 240 dot) Display size W149.8 x H57.4 mm
Setting display: Common to digital display
Display contents: Digital display
Channel display ( One-point/ multiple points continuous/sequential indication change) Display measuring value of each channel ( One-point/ multiple points continuous/sequential indication change) Clock display (Hour/Minute/Second/Tag/Unit) Chart speed display
Status display: RECORD ON ( lights during recording) LED KEY LOCK ( lights during key lock) ALARM ( lights during alarm activated) LED CHART END ( lights just before record ending) FAIL ( lights during unit abnormal time) * Sharing LED and setting display
Alarm Specifications

Alarm display : Occurrence CH No., data is displayed in red when alarm occurs
Alarm types: High limit, low limit
Alarm setting method: Individual setting for each point four levels/ channels
Alarm output:
(Option)
See option specification
General Specifications

Rated power voltage: 100 to 240V AC (universal power supply) 50/60Hz
Maximum power consumption: 100V A
Reference operating condition: Ambient temperature/ humidity range: 21 to 25 °C, 45 to 65%RH Power voltage: 90 to 264V Power frequency: 50/60Hz ±2% Attitude: Forward/ Backward/ Left/ Right within 3° Warm-up time: 1 hour or longer
Normal operating condition: Ambient temperature/humidity range 0 to 40°C, 20 to 80% RH Power voltage: 90 to 264V Power frequency: 50/60Hz ±2% Attitude: Forward/ Backward/ Left/ Right within 3°
Transportation condition: At the packed condition on shipment from our factory Ambient temperature/ humidity range: -20 to 60 °C, 5 to 90%RH (No dew condensation) Vibration: 10 to 60 Hz, 4.9m/ S2(0.5G or less) Impact: 392m/S2 (Approx. 40G or less)
Storage condition: Ambient temperature -20 to 60 °C, 5 to 90%RH (No dew condensation)
Working condition: Working temperature range 0 to 40 °C
Power failure protection: Programmed parameters stored into EEPROM memory Clock circuit sustained for 5 years or longer by a lithium battery (at the operation of 8 hours or longer per day)
Insulation resistance: Between primary terminals and protective conductor terminals --- 20MΩ or more at 500V DC Between secondary terminals and protective conductor terminals --- 20MΩ or more at 500V DC Between primary terminals and secondary terminals --- 20MΩ or more at 500V DC
Dielectric strength: Between primary terminals and protective conductor terminals --- 1 minute at 1500V AC Between secondary terminals and protective conductor terminals --- 1 minute at 500V AC Between primary terminals and secondary terminals --- 1 minute at 1500V AC Note 1: Primary terminals: power terminal, alarm output terminal, output relay terminal Secondary terminals: measuring input terminal, communication terminal, external drive terminal Note 2: When testing insulation resistance and dielectric strength, please short-circuit every terminals of primary and secondary terminals before the test. Test without short-circuiting terminals can damage instruments.
Case assembly material: Door (frame) --- ABS resin, Front panel --- Soda glass, Back case --- Normal steel
Color: Door(frame) --- White (Equivalent to DIC546 1/2), Front panel --- Transparent, Back case --- White (Equivalent to DIC546 1/2)
Mounting: Panel mounting
Weight: About 15kg (Full option)
Dimensions, panel cut: W400 x H260 x D300 mm (Dimensions) 388 x 248mm (Panel cut)
Terminal screws: Measuring input, alram terminals --- M3.5 Power, protective conductor terminal, external drive terminal, communication terminal --- M4
Chart paper illumination : White LED
Optional Specifications

External drive Chart 3- speed, chart stop, data printing, list printing, message printing 5 types, operation recording
Alarm output Mechanical relay ---- 12, 24, 36 points output, max contact capacity of 100 to 240V AC, 3A resistance load
Communication interface RS-422A or RS-485 + Ethernet + 1a contact output (1a contact output is contact output of mecha relay
Chart end output CHART END relay output when chart paper ended (communication interface is required)
FAIL output FAIL relay output when abnormality ( communication interface is required)
Receiving resistance for current input 250Ω( for 20mA) or 100Ω(for 50mA) are externally mounted to measure current
Communication interface specification

    With communication interface Without communication interface
Ethernet Specification Ethernet10BASE-T/ 100BASE-T, automated recognition, TCP, IP, HTTP, exclusive protocol -------------
Function Data display, parameter setting, with browser Data display, parameter setting on exclusive application -------------
RS-422ARS-485 Specification RS-422A, RS-485, Communication protocol: MODBUS Communication specification: 9600 bps to 19200 bps 7E1 to 8N2 -------------
Function Data display and parameter setting using exclusive application -------------
USB Specification Data display and parameter setting using exclusive application
Function Parameter setting for exclusive application