SE3000 series scanning units
are designed for data logging with a personal computer.
The basic unit with 6 input points can be connected to 7
sub units (6 input points / sub unit) and maximum 48
analog data can be collected. Two soft ware packages,
"KIDS" for data logging and "PASS" for parameter
programming, are available. |
 |
 |
|
Measuring point |
Base unit
6 points, sub unit 6-point/unit * Up to 7 sub
units can be connected to 1 base unit (up to 48
points). |
|
Input kind |
Universal
input 10 DC voltage, 17 thermocouples, 5
resistance thermometers |
|
Accuracy rating |
±0.1%±
1digit (for DC voltage and
thermocouples) |
|
Measuring cycle |
1 second
(for 6 points) to 8 seconds (for 48
points) |
|
Burnout |
Sensor
disconnection judgment function of thermocouples
and resistance thermometer inputs is built-in.
(Enable/disable selectable) |
|
Communications interface |
RS-232C,
RS-422A, RS-485 (switch selection) * MODBUS
protocol |
|
Alarm |
Up to 4
alarms for each channel |
|
Alarm type |
High, low,
differential high, differential low,
rate-of-change increase, rate-of change decrease
(no alarm output) |
|
Dimension |
Base unit
H138 x W72 x D100mm Sub unit H138 x W36 x
D100mm |
|
Mounting |
DIN (35mm)
rail mounting |
|
Rated power voltage |
100V to
240VAC 50/60Hz |
|
|
Display Unit Specifications (option,
later mounting available) |
|
Display unit |
7-segment
red LED 7 digits |
|
Display content |
Channel
number 2 digits, data 5 digits (channel
forwarding/fixed) |
|
Display renewal cycle |
3
seconds |
|
|