Sensor |
Humidity …
High Polymer capacitance type humidity
sensor Temperature … Semi-conductor type
temperature sensor |
|
Measuring range |
Humidity …
0 to 100%RH
|
Temperature
… |
-10 to 50°C (sensor
built-in type) -40 to 80°C (separated type,
probe type) | |
|
Accuracy rating |
|
Humidity
… |
±2%RH (at 0 to 90%RH
and 25°C) * Except for ±3%RH in 90 to 95%RH
(at 25°C) |
Temperature … ±0.5°C (0 to
50°C), ±1°C (except 0 to 50°C) |
|
Response time |
Shorter
than 15 seconds (at 90% response, 25°C and under
0.1m/s wind flow) |
|
Current data display |
Month,
day, hour, minute, relative humidity or dew-point
temperature, measured temperature |
|
Logging data storage |
Each 8000
data of temperature and humidity |
|
Data logging system |
Manual or
interval |
|
Data logging interval |
Continuous, 1 to 60 minutes (1 minute
increment) |
|
Read data replay |
Data
logged per year, month, day, hour and minute,
maximum/minimum/average temperature/humidity,
totalized temperature |
|
Functions |
High/low
alarm, totalizing reference temperature/totalizing
direction, logging repetition, auto-power-off,
etc. |
|
Communications |
RS-232C or
RS-485 |
|
Working temperature range |
-10 to
50°C (meter) |
|
Power supply |
AA
batteries or 100VAC (by AC adapter: sold
separately) |
|
Dimension/weight |
W64 x H113
x D32mm, about 140g (meter including
batteries) |